Consulting Services
High Sound Transmission-Loss Enclosure Design
- Designed an acoustic enclosure to isolate the noise produced by a noisy industrial pump.
- The design incorporated forced-air lined ducting to exhaust heat from the enclosure without losing the high transmission loss.
- A removable hatch allows accessibility to the equipment and easy maintenance.
| Solid model of the enclosure design. The cut-away section shows the lined ducting for sound-proof ventilation. | ![]() |
| The enclosure achieved an A-weighted sound reduction of 19 dB, as measured in a reverberation room. | ![]() |